TLC - PLC

HDPE solid wall pipes for HIGH VOLTAGE cables protection

2023-10-19T14:47:13+02:00

HDPE solid wall pipes for cable protection HIGH VOLTAGE
ELECTROPIPE – HV

BRIEF DESCRIPTION

High density polyethylene (HDPE) pipes with a solid wall profile, internally and externally smooth, black with red coextruded stripes on the external surface, connectable by butt polyfusion welding (verified according to ISO 13953) in order to be suitable also for the execution of trenchless poses (TOC).

In order to ensure the normal operation of the system with cable temperatures up to 80 ºC, and short-circuit temperatures (not exceeding 5 seconds) up to 160º C, the mechanical characteristics of the pipe meet the requirements of the following standards:

  • IEC 62067: Verification of the mechanical characteristics of HDPE conduits for cable insulation for nominal voltages from 150 to 500 kV, before and after thermal aging
  • ENA TS 12-24: verification of crushing strain resistance at 50 ºC and 75 ºC

The range of diameters includes:

  • all those required by CEI EN 61386, ɸ 25 to 250 mm, in various thicknesses for the different classes of annular rigidity
  • all sections up to ɸ 1200 mm, with reference to the SDR classes required by EN 12201-2

MAIN FEATURES & BENEFITS

  • IMQ certified standard 61386*
  • CE marking*
  • with PSV brand (Second Life Plastic) on request – Circular Economy
  • PE joint system with EPDM sealing seals, with IP66 and IP68 protection rating for ɸ 200 – 225 – 250 mm pipes
  • head/head and electrofusion joining system possible
  • 100% permanent watertight seal
  • internally and externally bevelled ends
  • Wide Radius Foldability
  • low elastic modulus
  • plastic behaviour in unstable situations
  • wide range of fittings and special parts, standard and customized
  • inertia to stray currents
  • high chemical resistance (ISO/TR 10358 – ISO/TR 7474)
  • High shock absorption capacity
  • total recyclability

* for the diameter range included in standard 61386

SPECIFICATION ITEMS

HDPE pipes for underground cable threading systems according to CEI EN 61386

Supply and installation of high-density polyethylene (HDPE) pipes, with solid wall profile, smooth internally and externally, black with coextruded red stripes on the external surface, for the construction of underground cable threading systems. The pipes must be equipped with a mark of conformity of the product to the standard CEI EN 61386-1-24 issued by an accredited third-party certification body, with crush resistance class ≥ … N and impact resistance classification “N series”.

Piping must be tested according to ISO 13953 by accredited third party to verify conformity to butt welds. The mechanical characteristics of HDPE cable insulation pipes with nominal voltages from 150 to 500 kV shall be verified according to IEC 62067, before and after thermal ageing. The verification of crushing deformation resistance at 50 ºC and 75 ºC shall be verified according to ENA TS 12-24. The marking of the pipes must bear in full all the elements required by the reference standard, in addition to the product quality mark and the CE marking. The pipe manufacturer must be regularly registered with the PolieCo Consortium (D.Lgs. 152/2006 – art. 234).

HDPE pipes – class 450* N

ɸ   50 mm (sp.   3,0 mm)
… ….. …
ɸ 200 mm (sp.   9,6 mm)
ɸ 225 mm (sp.  10,8 mm)
ɸ 250 mm (sp.  11,9 mm)

* Standard ring stiffness classes: 450 N – 750 N – >750 N

HDPE pipes for underground cable threading systems
for custom sizes not included in CEI EN 61386

Supply and installation of high-density polyethylene (HDPE) pipes, with solid wall profile, smooth internally and externally, black with coextruded red stripes on the external surface, for the construction of underground cable threading systems. The HDPE material of the pipes must meet the requirements of CEI EN 61386-1, and the normalized dimensional ratio must be SDR … according to UNI EN 12201-2. Piping must be tested according to ISO 13953 by accredited third party to verify conformity to butt welds. The mechanical characteristics of HDPE cable insulation pipes with nominal voltages from 150 to 500 kV shall be verified according to IEC 62067, before and after thermal ageing. The verification of crushing deformation resistance at 50 ºC and 75 ºC shall be verified according to ENA TS 12-24. The marking of the pipes must bear in full all the identifying elements of the product and the manufacturer, and repeat at intervals not exceeding 1 m. The manufacturer of pipes must be regularly registered with the mandatory PolieCo Consortium (D.Lgs. 152/2006 – art. 234).

HDPE pipes – SDR17*

… ….. …
ɸ   200 mm (sp. 11,9 mm)
ɸ   225 mm (sp. 13,4 mm)
ɸ   250 mm (sp. 14,8 mm)
… ….. …
ɸ 1200 mm (sp. 71,1 mm)

Standards: SDR26 (SN4) – SDR21 (SN8) – SDR17 (SN16) – SDR11 (SN64)

Upon request, this type of pipe can also be equipped with Pipe Tracer system, so as to become:

  • traceable with high plano-altimetric accuracy
  • referential (containing information on the type of service and its management)

YOU-TUBE

HDPE solid wall pipes for cable protection

2023-08-30T10:49:51+02:00

HDPE solid wall pipes for cable protection

BRIEF DESCRIPTION

High density polyethylene (HDPE) pipes with a solid wall profile, internally and externally smooth, black with red coextruded stripes on the external surface, connectable by butt polyfusion welding (verified according to ISO 13953) in order to be suitable also for the execution of trenchless poses (TOC).

In order to ensure the normal operation of the system with cable temperatures up to 80 ºC, and short-circuit temperatures (not exceeding 5 seconds) up to 160º C, the mechanical characteristics of the pipe meet the requirements of the following standards:

  • IEC 62067: Verification of the mechanical characteristics of HDPE conduits for cable insulation for nominal voltages from 150 to 500 kV, before and after thermal aging
  • ENA TS 12-24: verification of crushing strain resistance at 50 ºC and 75 ºC

The range of diameters includes:

  • all those required by CEI EN 61386, ɸ 25 to 250 mm, in various thicknesses for the different classes of annular rigidity
  • all sections up to ɸ 1200 mm, with reference to the SDR classes required by EN 12201-2

MAIN FEATURES & BENEFITS

  • IMQ certified standard 61386*
  • CE marking*
  • with PSV brand (Second Life Plastic) on request – Circular Economy
  • PE joint system with EPDM sealing seals, with IP66 and IP68 protection rating for ɸ 200 – 225 – 250 mm pipes
  • head/head and electrofusion joining system possible
  • 100% permanent watertight seal
  • internally and externally bevelled ends
  • Wide Radius Foldability
  • low elastic modulus
  • plastic behaviour in unstable situations
  • wide range of fittings and special parts, standard and customized
  • inertia to stray currents
  • high chemical resistance (ISO/TR 10358 – ISO/TR 7474)
  • High shock absorption capacity
  • total recyclability

* for the diameter range included in standard 61386

SPECIFICATION ITEMS

HDPE pipes for underground cable threading systems according to CEI EN 61386

Supply and installation of high-density polyethylene (HDPE) pipes, with solid wall profile, smooth internally and externally, black with coextruded red stripes on the external surface, for the construction of underground cable threading systems. The pipes must be equipped with a mark of conformity of the product to the standard CEI EN 61386-1-24 issued by an accredited third-party certification body, with crush resistance class ≥ … N and impact resistance classification “N series”.

Piping must be tested according to ISO 13953 by accredited third party to verify conformity to butt welds. The mechanical characteristics of HDPE cable insulation pipes with nominal voltages from 150 to 500 kV shall be verified according to IEC 62067, before and after thermal ageing. The verification of crushing deformation resistance at 50 ºC and 75 ºC shall be verified according to ENA TS 12-24. The marking of the pipes must bear in full all the elements required by the reference standard, in addition to the product quality mark and the CE marking. The pipe manufacturer must be regularly registered with the PolieCo Consortium (D.Lgs. 152/2006 – art. 234).

HDPE pipes – class 450* N

ɸ   50 mm (sp.   3,0 mm)         €/m ____,__
… ….. …
ɸ 200 mm (sp.   9,6 mm)        €/m ____,__
ɸ 225 mm (sp.  10,8 mm)       €/m ____,__
ɸ 250 mm (sp.  11,9 mm)        €/m ____,__

* Standard ring stiffness classes: 450 N – 750 N – >750 N

HDPE pipes for underground cable threading systems
for custom sizes not included in CEI EN 61386

Supply and installation of high-density polyethylene (HDPE) pipes, with solid wall profile, smooth internally and externally, black with coextruded red stripes on the external surface, for the construction of underground cable threading systems. The HDPE material of the pipes must meet the requirements of CEI EN 61386-1, and the normalized dimensional ratio must be SDR … according to UNI EN 12201-2. Piping must be tested according to ISO 13953 by accredited third party to verify conformity to butt welds. The mechanical characteristics of HDPE cable insulation pipes with nominal voltages from 150 to 500 kV shall be verified according to IEC 62067, before and after thermal ageing. The verification of crushing deformation resistance at 50 ºC and 75 ºC shall be verified according to ENA TS 12-24. The marking of the pipes must bear in full all the identifying elements of the product and the manufacturer, and repeat at intervals not exceeding 1 m. The manufacturer of pipes must be regularly registered with the mandatory PolieCo Consortium (D.Lgs. 152/2006 – art. 234).

HDPE pipes – SDR17*

… ….. …
ɸ   200 mm (sp. 11,9 mm)      €/m ____,__
ɸ   225 mm (sp. 13,4 mm)      €/m ____,__
ɸ   250 mm (sp. 14,8 mm)      €/m ____,__
… ….. …
ɸ 1200 mm (sp. 71,1 mm)       €/m ____,__

Standards: SDR26 (SN4) – SDR21 (SN8) – SDR17 (SN16) – SDR11 (SN64)

Upon request, this type of pipe can also be equipped with Pipe Tracer system, so as to become:

  • traceable with high plano-altimetric accuracy
  • referential (containing information on the type of service and its management)

YOU-TUBE

PVC solid wall pipes for cable protection

2023-07-20T08:20:30+02:00

PVC solid wall pipes for cable protection

BRIEF DESCRIPTION

Solid wall pipes made of polyvinyl chloride (PVC) with a smooth inner and outer surface, available in grey colour (RAL 7021). The diameters range (OD) goes from 50 up to 250 mm. Pipes are delivered in bars of 6 m with a built-in socket for glue connection or provided with a gasket. They are used for the construction of underground ducting networks.

 MAIN FEATURES

Ring stiffness: 450 – 750 N
Impact resistance class: L – N
CEI EN 61386 standard (with IMQ quality mark)
Socket connections with lip seal made of EPDM (EN 681)
Glue socket connections
High chemical and abrasion resistance
Inert to stray currents
It can be provided with PIPE TRACER, the plano-altimetric tracking system for underground pipelines

YOU-TUBE

Pipe tracer – geo localization + referenciation system for underground networks

2022-12-05T11:54:45+01:00

PIPE TRACER – Sistema di geolocalizzazione e referenziazione delle infrastrutture di rete interrate

DESCRIZIONE GENERALE

Sistema ad elevata precisione di geolocalizzazione + referenziazione delle infrastrutture di rete interrate, da posizionare sulla generatrice superiore esterna dei tubi da interrare. Il sistema è composto da:

  • un piccolo cavo di acciaio completamente rivestito di polietilene per essere isolato e protetto dall’aggressività dell’ambiente circostante (pH dei terreni, correnti vaganti, acqua)
  • connettori dritti e a TEE per i collegamenti stagni fra i cavi e con gli altri componenti
  • scatole di connessione in materiale plastico per l’immissione del segnale elettromagnetico, dotate di due alette in acciaio inox per consentire la “messa a terra”
  • jack di collegamento alla scatola di connessione per l’immissione del segnale elettromagnetico
  • piccoli pozzetti terminali in ghisa per alloggiare le singole scatole di connessione quando posizionate a terra su percorsi pedonali o carrabili
  • telaietti “WBH”* in plastica, fissabili alle pareti cementizie, plastiche o su pali, per posizionamento e fissaggio delle scatole di connessione e realizzazione del collegamento di messa a terra
  • tag RFID (Radio Frequency IDentification) – su richiesta – per registrazione e lettura elettronica delle informazioni di referenziazione dei singoli tratti di rete, posizionato all’interno dei pozzetti terminali di ghisa o sul cappuccio del telaio WBH

Il sistema installato rimane passivo durante tutto il suo periodo di vita, ma può essere attivato in qualsiasi momento immettendo un segnale elettromagnetico da qualsiasi scatola di connessione tramite apposito generatore (portatile esterno). Tale condizione rende il cavetto rintracciabile dagli appositi strumenti (disponibili in commercio in varie marche e tipi) con un elevato grado di precisione ottenendo coordinate GPS 3D. I tag RFID sono scrivibili e leggibili con strumenti specifici o con semplici smartphone dotati di tecnologia NFC.

* WBH: Wall Box Holder

PRINCIPALI CARATTERISTICHE

Elevato grado di precisione della localizzazione 3D
Redazione di mappe del sottosuolo precise
Implementazione della sicurezza degli operatori di cantiere
Riduzione dei tempi di intervento in caso di necessità
Deterrenza alle pose negligenti (esatta rilevazione della posizione e profondità di posa sullo stato di fatto)
Durabilità (inerzia chimica ed elettrica)
Idoneo per qualsiasi tipo di materiale, forma e dimensione dei tubi interrati
Segnale elettromagnetico idoneo per qualsiasi tipo di servizio (acqua, gas, energia, telefonia, fibre ottiche ecc.)
Facilità e velocità di installazione
Raccorderia specializzata a tenuta stagna
Sistema di referenziazione dei singoli tratti di condotte

Componenti

PE double wall corrugated pipes for telecom cable protection

2023-03-28T10:07:27+02:00

PE double wall corrugated pipes for telecom cable protection

BRIEF DESCRIPTION

Double wall corrugated pipes made of high density polyethylene (HDPE), smooth on the inside and corrugated on the outside. The diameters range (DN/OD) goes from 40 up to 200 mm and pipes are delivered in coils and bars. They find application in networks. Colours and performances are created in accordance with the client technical information. (the blue-blue colour is the “Telecom Italia” standard for fibre optic cables).

MAIN FEATURES

Wide range of diameters
Rings stiffness: 450-750 N
Impact resistance class: N
Small bending radius
Sleeve connections
Lightweight and quick to install
High chemical and abrasion resistance
Recyclable

YOU-TUBE

CERTIFICATES:

ITALIANA CORRUGATI

IMQ 450

BLACKCOR – PE double wall corrugated pipes for cable protection

2022-04-29T13:31:18+02:00

BLACKCOR Corrugated pipe for cable protection

BRIEF DESCRIPTION

Double wall corrugated pipes made of high density polyethylene (HDPE), smooth on the inside and corrugated on the outside, for cable protection networks.
Diameters (DN/OD) go from 40 up to 200 mm and pipes can be delivered in coils and bars.
The standard colour of the corrugated outer wall is available in 2 colours:

  • Black (with or without coextruded coloured stripes);
  • Red/orange

Upon request, pipes can be done in any desired colour.

MAIN FEATURES

Wide range of diameters
Ring stiffness: 450 – 750 N
Impact test classification: N
Close bending radius
Coupling connections
Highly resistance to UV (black colour) EN 1297
Lightweight and easy to install
High chemical and abrasion resistance
Inert to stray currents
Recyclable

YOU-TUBE

Fender – multiducts for fibre optic cables

2021-07-09T11:21:23+02:00

Fender – multiducts for fibre optic cables

BRIEF DESCRIPTION

Multiducts in fender configuration made of high density polyethylene, which consist of microducts smooth on the outside and the inner surface is provided with small axial reliefs in order to reduce the friction surface during the cables insertion. They are available in neutral standard colour, or, upon request, entirely coloured with or without the external coextruded coloured stripes. The range of diameters (OD) available is 12 – 14 mm, located on the same planar axle in varying numbers from 3 up to 7, individually wrapped in a HDPE sleeve which is also the separating lug between the microducts and makes the whole system solid. Cables are delivered in coils wrapped around wooden reels (or without reel on demand). They are used for the construction of underground network infrastructures for fibre optic cables insertion for telecommunications. This geometric configuration allows to place the pipes in the trenches in a horizontal or vertical position: this last type of installation is particularly suitable for small trenches installations.

Microducts are also available in these two versions:

  • With gliding silicone applied on the inner surface
  • With anti rodents additive

MAIN FEATURES

100% permanent tightness
Excellent bending
Excellent smoothness
Particularly suitable for small trenches installations
High UV resistance (coloured versions)
Plastic behaviour in unstable situations
Customisable thicknesses
Inert to stray currents
High chemical resistance (ISO/TR 10358)
High shock absorption capacity
Recyclable

YOU-TUBE

Contact Us

    Privacy Policy

    * 1) I declare I read the Privacy policy of this website.
      2) We would like to use your personal data in order to keep you update through e-mails, instant messages, chats or phone calls on news and commercial offers concerning our products and services and the third parties ones, and also concerning other marketing activities mentioned in the C letter. Please note that you can always change your decision and refuse the processing of your personal data for marketing purposes by contacting us through the e-mail address privacy.systemgroup@tubi.net .
      3) We would like to share your personal data with the other companies that belong to “System Group” and the partners in order to be processed for commercial and marketing purposes.

    Go to Top